A Generator Transfer Switch makes the connection between a generator and the electrical circuits in a home or business. Generator Transfer Switches allows a safe, reliable, code-compliant generator installation.
Generator Transfer Switch
A Generator Transfer Switch makes the connection between a generator and the electrical circuits in a home or business. Generator Transfer Switches allow a safe, reliable, code-compliant generator installation for automatic standby generators or portables.
Two different sources of power—the electric utility and the generator—should never meet. Transfer Switches select between the primary source of power (the electric utility) and the generator. They “Transfer” the electrical load from one source to the other by breaking the connection to the first source before connecting to the second source.
Transfer Switch
A Transfer Switch works like a 3-position switch for utility power, off, and generator power. To switch from utility power to generator power, the switch must engage the off position before it selects generator power. This “break before make” type of Generator Transfer Switch isolates the building from the electric utility anytime the generator provides power. Isolation protects the generator from possible catastrophic damage and utility workers and neighbors from unexpected exposure to power from the generator.
Transfer Switch for Generator
Generator transfer switches fit two categories—manual and automatic. Standby or backup generators provide power during an outage and work without human intervention. An automatic generator transfer switch works with the generator to detect an outage, start the generator, and switch the building electrical system to generator power. When the utility restores power, the transfer switch disconnects the generator and reconnects utility power.
Manually operated transfer switches require someone to move the switch from utility power to generator power. In a typical home installation for a portable generator, the owner connects the generator cable to the inlet box and the generator. They start the generator and wait a few moments for the engine to warm. When the generator is ready, the homeowner moves the transfer switch from the utility position to the generator position. When the utility restores power, the operator switches back to utility power and shuts down the generator.
Choosing a Transfer Switch—Generator
A service rated generator transfer switch meets electrical codes to work as a service disconnect. A transfer switch also has a current rating in amps like200-Amps, for example. The transfer switch current rating must equal or exceed equipment rating it serves. A main circuit breaker panel with a 200-Amp main breaker requires a transfer switch for generator with a 200-Amp or higher rating.
The electric utility delivers single-phase power to homes and many small businesses, and three-phase power to larger businesses and buildings. A transfer switch for a generator matches the phase requirements of the building and electrical service it serves.
Standby generator manufacturers build transfer switches designed to work with their generators to implement specific features. To take full advantage of all the generator features, choose a generator transfer switch suggested by the manufacturer. Other models may not work or implement all the features. Packages that include a standby generator and a generator transfer switch save money and guarantee compatibility.
The Best Transfer Switch
Visit our Power-Expert (top menu) for more information on transfer switches and how to choose the best model for your installation. The right generator transfer switch provides a safe and reliable connection for utility and generator power.
Related Generator Transfer Switch Categories
50-Amp Automatic | 100-Amp Automatic | 150-Amp Automatic | 200-Amp Automatic
240-Volt Single Phase | 208-Volt Three-Phase | 240-Volt Three Phase | 480-Volt Three Phase
Manual Switches | 30-Amp Kit | 50-Amp Kit | 100-Amp | 200-Amp | 30-Amp
-
Model #: A040C970
Cummins Onan OTEC 400 Amp 208V Three Phase Automatic Transfer Switch Nema 3R | A040C970
Norwall's Low Price
$3,334.00 -
Model #: A040C969
Cummins Onan OTEC 400 Amp 480V Three Phase Automatic Transfer Switch Nema 1 | A040C969
Norwall's Low Price
$2,911.00 -
Model #: A040C967
Cummins Onan OTEC 400 Amp 240V Three Phase Automatic Transfer Switch Nema 1 | A040C967
Norwall's Low Price
$2,911.00 -
Model #: A040C966
Cummins Onan OTEC 400 Amp 208V Three Phase Automatic Transfer Switch Nema 1 | A040C966
Norwall's Low Price
$2,911.00 -
Model #: A040C980
Cummins Onan OTEC 225 amp 480V Three Phase Automatic Transfer Switch Nema 3R | A040C980
Norwall's Low Price
$2,628.00 -
Model #: A040C979
Cummins Onan OTEC 225 Amp 480V Three Phase Automatic Transfer Switch Nema 1 | A040C979
Norwall's Low Price
$2,267.00 -
Model #: A040C978
Cummins Onan OTEC 225 Amp 208V Three Phase Automatic Transfer Switch Nema 3R | A040C978
Norwall's Low Price
$2,628.00 -
Model #: A040C977
Cummins Onan OTEC 225 Amp 208V Three Phase Automatic Transfer Switch Nema 1 | A040C977
Norwall's Low Price
$2,267.00 -
Model #: A040V598
Cummins Onan OTEC Service Entrance Rated 225 Amp 240V Single Phase Automatic Transfer Switch Nema 3R | A040V598
Norwall's Low Price
$4,878.00 -
Model #: A040C964
Cummins Onan OTEC 125 Amp 480V Three Phase Automatic Transfer Switch Nema 3R | A040C964
Norwall's Low Price
$1,887.00 -
Model #: A040C963
Cummins Onan OTEC 125 Amp 480V Three Phase Automatic Transfer Switch Nema 1 | A040C963
Norwall's Low Price
$1,580.00 -
Model #: A040C962
Cummins Onan OTEC 125 Amp 208V Three Phase Automatic Transfer Switch Nema 3R | A040C962
Norwall's Low Price
$1,887.00
A Generator Transfer Switch makes the connection between a generator and the electrical circuits in a home or business. Generator Transfer Switches allows a safe, reliable, code-compliant generator installation.
Generator Transfer Switch
A Generator Transfer Switch makes the connection between a generator and the electrical circuits in a home or business. Generator Transfer Switches allow a safe, reliable, code-compliant generator installation for automatic standby generators or portables.
Two different sources of power—the electric utility and the generator—should never meet. Transfer Switches select between the primary source of power (the electric utility) and the generator. They “Transfer” the electrical load from one source to the other by breaking the connection to the first source before connecting to the second source.
Transfer Switch
A Transfer Switch works like a 3-position switch for utility power, off, and generator power. To switch from utility power to generator power, the switch must engage the off position before it selects generator power. This “break before make” type of Generator Transfer Switch isolates the building from the electric utility anytime the generator provides power. Isolation protects the generator from possible catastrophic damage and utility workers and neighbors from unexpected exposure to power from the generator.
Transfer Switch for Generator
Generator transfer switches fit two categories—manual and automatic. Standby or backup generators provide power during an outage and work without human intervention. An automatic generator transfer switch works with the generator to detect an outage, start the generator, and switch the building electrical system to generator power. When the utility restores power, the transfer switch disconnects the generator and reconnects utility power.
Manually operated transfer switches require someone to move the switch from utility power to generator power. In a typical home installation for a portable generator, the owner connects the generator cable to the inlet box and the generator. They start the generator and wait a few moments for the engine to warm. When the generator is ready, the homeowner moves the transfer switch from the utility position to the generator position. When the utility restores power, the operator switches back to utility power and shuts down the generator.
Choosing a Transfer Switch—Generator
A service rated generator transfer switch meets electrical codes to work as a service disconnect. A transfer switch also has a current rating in amps like200-Amps, for example. The transfer switch current rating must equal or exceed equipment rating it serves. A main circuit breaker panel with a 200-Amp main breaker requires a transfer switch for generator with a 200-Amp or higher rating.
The electric utility delivers single-phase power to homes and many small businesses, and three-phase power to larger businesses and buildings. A transfer switch for a generator matches the phase requirements of the building and electrical service it serves.
Standby generator manufacturers build transfer switches designed to work with their generators to implement specific features. To take full advantage of all the generator features, choose a generator transfer switch suggested by the manufacturer. Other models may not work or implement all the features. Packages that include a standby generator and a generator transfer switch save money and guarantee compatibility.
The Best Transfer Switch
Visit our Power-Expert (top menu) for more information on transfer switches and how to choose the best model for your installation. The right generator transfer switch provides a safe and reliable connection for utility and generator power.
Related Generator Transfer Switch Categories
50-Amp Automatic | 100-Amp Automatic | 150-Amp Automatic | 200-Amp Automatic
240-Volt Single Phase | 208-Volt Three-Phase | 240-Volt Three Phase | 480-Volt Three Phase
Manual Switches | 30-Amp Kit | 50-Amp Kit | 100-Amp | 200-Amp | 30-Amp